Contact Us

Use the form on the right to contact us.

You can edit the text in this area, and change where the contact form on the right submits to, by entering edit mode using the modes on the bottom right. 

1165 Allgood Road Northeast, Suite 20
Marietta, GA, 30062
United States

(678)560-9172

CT03 Encapsulated Current Sense Transformers

ICE Components CT03 Series current sense transformers.


FEATURES

• 25A Current Rating
• Constructed to meet UL1950 and EN60950 creepage/clearance spacing.
• Available in unpotted (Figure A) and epoxy potted (Figure B) versions.
• Available in unipolar and bipolar configurations Meets UL Class B insulation system.
• Frequency Range of 1kHz to 5kHz
 

PACKAGING

• Pieces/Tray: 144
• Trays/Box: 12
• Pieces/Box: 1,728

APPLICATIONS

• Feedback Control
• Overload Protection
• Detecting Load Drop or Shutdown
 

C  -   Center Tap Secondary
N  -   Non-Center Tap Secondary

  -  Samples Available

 CT03 Encapsulated Current Transformer
Part Number Turns Ratio Ls (mH,min) Rs (Ω,max) Hi Pot (VAC)
CT03-050-B_C 1:50 5 0.6 3,750
CT03-100-B_C 1:100 20 1.3 3,750
CT03-200-B_C 1:200 80 4.5 3,750
CT03-750-A_C 1:750 1,125 34.0 3,750
CT03-1000-A_C 1:1,000 1,500 57.0 3,750
CT03-050-B_N 1:50 5 0.6 3,750
CT03-100-B_N 1:100 20 1.3 3,750
CT03-200-B_N 1:200 80 4.5 3,750
CT03-750-A_N 1:750 1,125 34.0 3,750
CT03-1000-A_N 1:1,000 1,500 57.0 3,750

TEST CONDITIONS:

• Rs (max): Electrical specifications at 25ºC.
• Operating temperature range: -40ºC to +130ºC. This is a combination of ambient plus temperature rise.
• Meets UL 94V-0.

Specifications subject to change without prior notice.