CT06 Current Sense Transformers

ICE Components CT06 Series current sense transformers are rated at 18A and feature the smallest footprint in the industry.

CT06 SERIES

(Current Sense Transformer)


FEATURES

• Small Footprint
• Hi-Pot tested at 1,500 VAC
• Current Ratings to 18A
• Patent Pending
• Meets basic creepage

APPLICATIONS

• DC/DC Converters
• AC/DC Converters
• POL Converters

PACKAGING

• Reel dia: 13”, Carrier width: 16mm, Pcs/reel: 1,000, Reel per carton: 10

 

  -  Parts available @ Mouser

Part Number Turns Ratio E-T Product Ls (min) Rs (max) Current Rating Hi Pot
CT06-050 1:50 27 V-μs 0.35 mH 1.3 Ω 18.0 A 1500 VAC
CT06-100 1:100 54 V-μs 1.40 mH 4.8 Ω 18.0 A 1500 VAC
CT06-150 1:150 81 V-μs 3.15 mH 15.2 Ω 18.0 A 1500 VAC
CT06-200 1:200 110 V-μs 5.60 mH 25.0 Ω 18.0 A 1500 VAC
CT06-250 1:250 135 V-μs 8.75 mH 37.2 Ω 18.0 A 1500 VAC

TEST CONDITIONS:

Current Rating: DC current through primary, plus turns-ratio-divided DC current through secondary winding, to cause a 40°C temperature rise at 25°C ambient.
Ls (min): Tested at 10kHz, 0.1Vrms.
Rs (max): Electrical specifications at 25°C.

• Tested at 10kHz, 0.1Vrms.
• Electrical specifications at 25°C.
• Operating range: -40°C to +130°C. This is a combination of ambient plus temperature rise.
• Meets UL 94V-0.
• DC current through primary, plus turns-ratio-divided DC current through secondary winding, to cause a 40°C temperature rise at 25°C ambient.
• Meets RXT-2 Class F Insulation System (E169423).