Part Number |
Burden (Rb) | Current Rating | ET Product | Frequency Range | Hi Pot | Ls (min) | Rp ref. | Rs (max) | Turns Ratio |
Order FREE SAMPLES |
| CT02-050 | 50 Ω | 15.0 Apk | 4.0 V-μs | 0.10-2.0 MHz | 1500 VAC | 0.44 mH | 0.008 Ω | 0.85 Ω | 1:50 |
|
| CT02-100 | 100 Ω | 18.0 Apk | 8.0 V-μs | 0.10-2.0 MHz | 1500 VAC | 1.8 mH | 0.008 Ω | 4.8 Ω | 1:100 |
|
| CT02-150 | 150 Ω | 18.0 Apk | 12.0 V-μs | 0.10-2.0 MHz | 1500 VAC | 4 mH | 0.008 Ω | 15.0 Ω | 1:150 |
|
| CT02-200 | 200 Ω | 18.0 Apk | 16.0 V-μs | 0.10-1.0 MHz | 1500 VAC | 7.1 mH | 0.008 Ω | 25.0 Ω | 1:200 |
|
| CT02-250 | 250 Ω | 18.0 Apk | 20.0 V-μs | 0.10-1.0 MHz | 1500 VAC | 11.1 mH | 0.008 Ω | 37.2 Ω | 1:250 |
|
| Test Conditions: Current Rating: Peak current (50% duty cycle) through primary (1-2) to cause 40°C temperature rise at 25°C ambient with recommended burden resistance (Rb) connected to secondary (3-4). Ls (min): Tested @ 10kHz, 0.1Vrms. Rs (max): Electrical specifications at 25ºC. |
|
|